Hardware setup6 min readUpdated 2026-11-15

Adding a Scanner Scale (Datalogic & Zebra)

Connect Datalogic Magellan or Zebra MP-series combo scanner scales using USB-OEM mode, configure lb/kg units and Type 2 pricing in Basket POS, and resolve weight or scan issues.

Required mode
USB-OEM (IBM Table-Top Scanner & Scale)
Where in Basket POS
Settings → Hardware → Scanner Scale
Applies to
Datalogic Magellan (9800i, 9400i, 9300i, 8400) · Zebra / Symbol (MP7000, MP72, MP6000) · Basket POS

Before you start

  • A supported combo scanner scale: Datalogic Magellan series (Vendor ID 0x05F9) or Zebra / Symbol MP series (Vendor ID 0x05E0).
  • The manufacturer’s external AC power supply connected to the scanner scale (USB bus power alone cannot run a table-top scanner scale).
  • A USB-OEM POS cable connecting the scanner scale to the Basket POS terminal or a powered USB hub.
  • Your manufacturer programming sheet or utility (Datalogic configuration barcodes or Zebra 123Scan) if the unit is not already in USB-OEM mode.

Required scanner-scale mode: USB-OEM

Basket POS communicates directly with both the scanner and the integrated weigh platter over a single USB cable using native USB-OEM interfaces ("Table-top Scanner" and "Scale"). Keyboard wedge (HID) mode cannot transmit scale weights or use the native USB interface.

Important: Do not use USB Keyboard Wedge (HID) or RS-232 Serial mode.
Datalogic interface mode

USB-OEM (USB-POS / IBM Table-Top)

Exposes both "Table-top Scanner" and "Scale" USB interfaces. Datalogic uses 2-byte scale status reporting, handled automatically.

Zebra / Symbol interface mode

IBM Table-Top USB (USB-OEM) with Scale Enabled

Basket POS auto-detects Symbol Technologies devices and applies Zebra’s scale byte layout automatically.

Coupons & 2D barcodes

GS1 DataBar Expanded + Transmit AI (8110); QR & Code 128 enabled

Required for manufacturer coupons (AI 8110) and store discount QR codes.

Receipt & order QRs

Handled by Hand Scanner (HID mode)

Counter scanner scales ring items, coupons, and wallet passes—order and receipt lookup QRs must be scanned with the HID hand scanner.

POS weight & label settings

English (lb) or Metric (kg) · Type 2 price: 4 digit or 5 digit

Must match your scanner-scale firmware unit and deli/scale-printed Type 2 barcode format.

Step-by-step setup

  1. 1

    Set the scanner scale to USB-OEM mode

    Before connecting to Basket POS (or if the unit was previously used in keyboard-wedge mode), configure the hardware interface to USB-OEM.

    • Datalogic (Magellan): Scan the Enter Programming Mode barcode from your Magellan manual, scan USB-OEM (also listed as USB-POS / IBM Table-Top), ensure the integrated Scale interface is enabled, and scan Exit Programming Mode.
    • Zebra / Symbol (MP7000 / MP72): Use Zebra 123Scan or the MP-series programming guide to set USB Device Type to IBM Table-Top USB (USB-OEM) and verify Scale Communication over USB-OEM is enabled.
    • Enable GS1 DataBar Expanded with Application Identifier (AI) transmission so 8110 manufacturer coupons pass their full record.

    Why Keyboard Wedge (HID) will not work here

    In HID Keyboard mode, the counter unit only types barcode characters—Android and Basket POS cannot see the "Table-top Scanner" or "Scale" USB interfaces, so scale weight will stay blank.

  2. 2

    Connect power and USB to the POS terminal

    Table-top scanner scales draw significantly more power than handhelds and require dedicated AC power.

    • Plug the scanner scale’s external AC power adapter into the power port on the unit and into a wall outlet or surge protector.
    • Wait for the unit to complete its power-on self-test (platter light and beep). Make sure nothing is resting on the weigh platter during startup.
    • Plug the USB cable from the scanner scale’s host/POS port into an available USB port on the Basket POS terminal.
  3. 3

    Select the scanner scale in Basket POS Hardware settings

    Bind the USB device to the register lane and align the weight and barcode settings.

    • In Basket POS, open the side menu and tap Settings → Hardware.
    • Tap Scanner Scale and choose your device from the list (shown by manufacturer and model, such as Datalogic ... or Symbol Technologies ...).
    • Set Scale Weight Unit to English (lb) or Metric (kg) to match the unit configured on the scale hardware.
    • Set Type 2 price to 4 digit ($0.00–$99.99) or 5 digit ($0.00–$999.99) to match how your deli and meat scales encode prices into Type 2 barcodes.
    • Optional: Enable Allow manual weight entry if you want cashiers to be able to type a weight on the numpad when a scale is disconnected.
    • Tap Save in the top-right corner of the Hardware card.
  4. 4

    Grant Android USB permission on the Register screen

    Android requires explicit permission the first time Basket POS claims the USB scanner and scale interfaces.

    • Navigate back to the Register screen.
    • When Android shows "Allow Basket POS to access <device>?", check Always open / Use by default for this USB device and tap OK.
    • If a second prompt appears after re-initializing, tap OK again so both the scanner and scale interfaces stay authorized across reboots.

Verify your setup

  • Confirm the live weight display on the register shows 0.00 lb (or 0.000 kg) when the platter is empty, rather than "--".
  • Place a test weight or produce item on the platter and verify the live weight updates smoothly and settles.
  • Scan a standard product UPC and confirm the item rings up immediately.
  • If your store sells scale-labeled items, scan a Type 2 barcode and verify the embedded price matches the label.

Troubleshooting

If the hardware does not behave as expected, match what you are seeing below:

Scanner scale does not appear in the Settings → Hardware dropdown

Likely cause

  • The unit is not receiving external AC power or the USB cable is loose.
  • The scanner is set to RS-232 serial mode instead of USB-OEM.

How to fix

  1. 1.Verify the external power brick is plugged in and the scanner scale powers on with its indicator lights active.
  2. 2.Reseat the USB cable at both the scanner scale and POS terminal (avoid unpowered passive USB splitters).
  3. 3.Program the scanner to USB-OEM mode, power-cycle it, then close and reopen Settings → Hardware.

Scanner beeps when scanning a barcode, but nothing rings into Basket POS

Likely cause

  • The scanner is in USB Keyboard Wedge (HID) or Virtual COM mode instead of USB-OEM.
  • Android USB permission was denied or expired.

How to fix

  1. 1.Switch the scanner interface to USB-OEM (IBM Table-Top Scanner) using the manufacturer’s programming barcodes.
  2. 2.Confirm the correct device is selected and saved under Settings → Hardware → Scanner Scale.
  3. 3.Return to Register and accept the Android USB permission prompt (check "Always allow").

Scale weight shows "--" or will not settle on a weight

Likely cause

  • Something is touching or binding the weigh platter (produce bag, crumbs, counter edge, or protective shipping insert).
  • The scale is under-zero, over-capacity, warming up, or needs to be zeroed.
  • The Scale interface was not enabled inside the USB-OEM configuration.

How to fix

  1. 1.Lift the platter, clear any debris underneath, and make sure the platter sits freely without rubbing the surrounding counter.
  2. 2.With the platter completely empty, press the physical Zero button on the scanner-scale bezel.
  3. 3.In Basket POS, go to Settings → Hardware and tap Reboot Scanner Scale, or power-cycle the scanner scale with an empty platter.
  4. 4.If scanning works but weight still never appears, verify Scale over USB-OEM is enabled in the scanner’s programming.

Scale-printed Type 2 deli/meat labels ring up at the wrong price (off by 10x or misread)

Likely cause

  • The Type 2 price digit setting (4 digit vs 5 digit) in Basket POS does not match the deli scale’s label format.

How to fix

  1. 1.Go to Settings → Hardware → Type 2 price.
  2. 2.Choose 4 digit ($0.00–$99.99) if the barcode uses a price check digit, or 5 digit ($0.00–$999.99) if all 5 digits represent the price.
  3. 3.Tap Save and re-scan the label.

Manufacturer coupons (8110) fail or ring up as "Item not found"

Likely cause

  • GS1 DataBar Expanded is disabled or Application Identifiers (AI) are not being transmitted.

How to fix

  1. 1.In your Datalogic or Zebra configuration, enable GS1 DataBar Expanded and enable Transmit Application Identifier (AI) so the payload starts with 8110.

Scanner scale stops responding after an accidental unplug

Likely cause

  • Android dropped the active USB handle when the cable disconnected.

How to fix

  1. 1.Reconnect the USB cable and wait 10–15 seconds—Basket POS automatically attempts to re-claim the USB connection.
  2. 2.If it does not recover, open Settings → Hardware and tap Reboot Scanner Scale, then return to Register.